PE Foam Insulating Band (with Adhesive)

It is used; in insulating of the with big diameter, water and similar part, which can not be insulated with insulating pipe for any reason, In the plasterworks applications, in the jointing places of the plaster with ceiling and base coating, or as a preventer of heat bridgebetween profile and wall or profile and plaster.

It is not permeable because of its closed cell structure. Can be easily applied because of sticky one side.

 

Technical characteristics:

Head conductivity Coefficient: (W/mK) 0,043 – 0,045 (TS 388 – TS 415)
Endurance to head : -45°C 95°C
Density: 25 - 40 kg/m3
Deformation under pressure: 75% compression (72 hour)
(ISO 1856) 60% - 63%
Compression strength : 25% compression 0,31 kgf/cm2
ISO 1856 method C: 50% compression 0,91 kgf/cm2
75% compression 2,83 kgf/cm2
Water absorption Sensitivity: Maximum 0,42% of the volume after being plunged in the water and waited here for 24 hours in the room temperature
Tolerances: ± 3 % length ± 0,5 mm. thickness.
Toleranslar:  
 
Fig.1 Production values